{"title":"Special Offers","description":"","products":[{"product_id":"time-delay-relay-230-v-ac-on-delay48-x-48-mm","title":"Time delay relay 230 V\/AC (ON DELAY)48 x 48 mm","description":"\u003cp\u003e\u003cstrong\u003eTime delay ON-DELAY built-in monofunctional relay 230 V\/AC with 1 switching contact.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe time delay\/time relay is used to switch loads in stages: electric boilers, furnaces, heaters, etc. and thus prevents current surges in the network and tripping of circuit breakers due to large overvoltages.\u003c\/p\u003e\u003cp\u003eIt can also be used to coordinate the switch-on time of several devices in machines, appliances or other equipment.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTime range:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eERP-03Y - 0-3 s\u003c\/p\u003e\u003cp\u003eERP-12Y - 0-12 s\u003c\/p\u003e\u003cp\u003eERP-30Y - 0-30 s\u003c\/p\u003e\u003cp\u003eERP-60Y - 0-60 s\u003c\/p\u003e\u003cp\u003eERP-03DY - 0-3 min.\u003c\/p\u003e\u003cp\u003eERP-12DY - 0-12 min.\u003c\/p\u003e\u003cp\u003eERP-30DY - 0-30 min.\u003c\/p\u003e\u003cp\u003eERP-60DY - 0-60 min.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"0-3s","offer_id":56747286495613,"sku":"ERP-03Y","price":17.84,"currency_code":"EUR","in_stock":false},{"title":"0-12s","offer_id":56747286528381,"sku":"ERP-12Y","price":17.84,"currency_code":"EUR","in_stock":true},{"title":"0-30s","offer_id":56747286593917,"sku":"ERP-30Y","price":16.0,"currency_code":"EUR","in_stock":true},{"title":"0-60s","offer_id":56747286790525,"sku":"ERP-60Y","price":17.84,"currency_code":"EUR","in_stock":false},{"title":"0-3min","offer_id":56747286823293,"sku":"ERP-03DY","price":17.84,"currency_code":"EUR","in_stock":true},{"title":"0-12min","offer_id":56747286888829,"sku":"ERP-12DY","price":17.84,"currency_code":"EUR","in_stock":false},{"title":"0-30min","offer_id":56747286954365,"sku":"ERP-30DY","price":17.84,"currency_code":"EUR","in_stock":true},{"title":"0-60min","offer_id":56747286987133,"sku":"ERP-60DY","price":17.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_78fe07f6-4e96-4320-8c8e-35379d06c00d.png?v=1755784855"},{"product_id":"three-phase-monitoring-protection-relay-for-overvoltage-undervoltage-sequence-fault-control-1","title":"Three-phase monitoring\/protection relay for overvoltage, undervoltage, sequence\/fault control","description":"\u003cp\u003e\u003cstrong\u003eThree-phase monitoring\/protection relay for controlling overvoltage, undervoltage, sequence, phase failure with timer. GKT-03\/03F (ENERGIZED)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003ePhase protection relays are designed to protect three-phase loads from damage caused by line voltage.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\t\u003cli\u003eVoltage: 400 V - 510 V AC (adjustable)\u003c\/li\u003e\t\u003cli\u003eUndervoltage: 260V - 370V AC (adjustable)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eTimer: 0.1 s - 20 s (adjustable)\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003ePhase failure protection\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003ePhase sequence control (GKT-03F)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eDIN rail mounting\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eWidth 35.4 mm\u003c\/p\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Yes","offer_id":56749117964669,"sku":"GKT-03F","price":47.76,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":56749117997437,"sku":"GKT-03","price":49.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_e6c7b017-d4d4-4f1c-ab35-bacb03e9b5f3.png?v=1755800079"},{"product_id":"three-phase-monitoring-protection-relay-for-overvoltage-undervoltage-sequence-fault-control-2","title":"Three-phase monitoring\/protection relay for overvoltage, undervoltage, sequence\/fault control","description":"\u003ch1 data-start=\"184\" data-end=\"249\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"186\" data-end=\"247\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eThree-phase relay for voltage monitoring - GKM-02F (TENSE)\u003c\/font\u003e\u003c\/span\u003e\u003c\/h1\u003e\u003cp data-start=\"250\" data-end=\"351\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"250\" data-end=\"351\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOvervoltage\/undervoltage monitoring - Phase sequence - Zero presence check - 5A output - 140-300 VAC\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp data-start=\"353\" data-end=\"709\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe three-phase monitoring relay \u003cspan data-start=\"381\" data-end=\"392\" style=\"font-weight: 600;\"\u003eGKM-02F\u003c\/span\u003e from \u003cspan data-start=\"404\" data-end=\"413\" style=\"font-weight: 600;\"\u003eTENSE\u003c\/span\u003e is designed to protect three-phase loads from dangerous status deviations in the power supply network. The device monitors for undervoltage, overvoltage, phase loss, incorrect phase sequence and neutral conductor failure.\u003cbr data-start=\"616\" data-end=\"619\"\u003eWhen a fault is detected, the relay immediately disconnects the output contact, protecting the connected equipment.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"716\" data-end=\"741\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"719\" data-end=\"741\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey Features\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul data-start=\"743\" data-end=\"1789\"\u003e\n\u003cli data-start=\"743\" data-end=\"876\"\u003e\u003cp data-start=\"745\" data-end=\"876\"\u003e\u003cspan data-start=\"745\" data-end=\"772\" style=\"font-weight: 600;\"\u003eOvervoltage Monitoring (HV):\u003c\/span\u003e\u003cbr data-start=\"772\" data-end=\"775\"\u003e- Reacts to exceeding the set level in any phase\u003cbr data-start=\"835\" data-end=\"838\"\u003e- Setting range: \u003cspan data-start=\"860\" data-end=\"876\" style=\"font-weight: 600;\"\u003e230-300 VAC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"878\" data-end=\"997\"\u003e\u003cp data-start=\"880\" data-end=\"997\"\u003e\u003cspan data-start=\"880\" data-end=\"907\" style=\"font-weight: 600;\"\u003eUndervoltage monitoring (LV):\u003c\/span\u003e\u003cbr data-start=\"907\" data-end=\"910\"\u003e- Responds to voltage drop in any phase\u003cbr data-start=\"956\" data-end=\"959\"\u003e- Setting range: \u003cspan data-start=\"981\" data-end=\"997\" style=\"font-weight: 600;\"\u003e140-210 V AC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1106\"\u003e\u003cp data-start=\"1001\" data-end=\"1106\"\u003e\u003cspan data-start=\"1001\" data-end=\"1035\" style=\"font-weight: 600;\"\u003eAdjustable response time (DT):\u003c\/span\u003e\u003cbr data-start=\"1035\" data-end=\"1038\"\u003e- Delay in response to a fault condition\u003cbr data-start=\"1075\" data-end=\"1078\"\u003e- range: \u003cspan data-start=\"1090\" data-end=\"1106\" style=\"font-weight: 600;\"\u003e0.1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1228\"\u003e\u003cp data-start=\"1110\" data-end=\"1228\"\u003e\u003cspan data-start=\"1110\" data-end=\"1152\" style=\"font-weight: 600;\"\u003eAutomatic reset - return time (RT):\u003c\/span\u003e\u003cbr data-start=\"1152\" data-end=\"1155\"\u003e- Power-on delay after voltage normalization\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e- range: \u003cspan data-start=\"1212\" data-end=\"1228\" style=\"font-weight: 600;\"\u003e0.1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1355\"\u003e\u003cp data-start=\"1232\" data-end=\"1355\"\u003e\u003cspan data-start=\"1232\" data-end=\"1278\" style=\"font-weight: 600;\"\u003ePhase sequence and phase presence monitoring\u003c\/span\u003e\u003cbr data-start=\"1278\" data-end=\"1281\"\u003e- Protection against incorrect phase sequence\u003cbr data-start=\"1328\" data-end=\"1331\"\u003e- phase failure detection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1511\"\u003e\u003cp data-start=\"1359\" data-end=\"1511\"\u003e\u003cspan data-start=\"1359\" data-end=\"1407\" style=\"font-weight: 600;\"\u003ePresence of neutral conductor (N) monitoring\u003c\/span\u003e\u003cbr data-start=\"1407\" data-end=\"1410\"\u003e- Protection against loss of N conductor in the network\u003cbr data-start=\"1450\" data-end=\"1453\"\u003e- Disconnection when supply voltage drops below \u003cspan data-start=\"1500\" data-end=\"1511\" style=\"font-weight: 600;\"\u003e88 V AC\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1591\"\u003e\u003cp data-start=\"1515\" data-end=\"1591\"\u003e\u003cspan data-start=\"1515\" data-end=\"1532\" style=\"font-weight: 600;\"\u003eHysteresis 3%\u003c\/span\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003e- limits unwanted fast switching during voltage fluctuations\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1593\" data-end=\"1660\"\u003e\u003cp data-start=\"1595\" data-end=\"1660\"\u003e\u003cspan data-start=\"1595\" data-end=\"1618\" style=\"font-weight: 600;\"\u003eOptical signalling\u003c\/span\u003e\u003cbr data-start=\"1618\" data-end=\"1621\"\u003e- LED indicators for status and fault type\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1662\" data-end=\"1708\"\u003e\u003cp data-start=\"1664\" data-end=\"1708\"\u003e\u003cspan data-start=\"1664\" data-end=\"1708\" style=\"font-weight: 600;\"\u003eCompact design, DIN rail mounting\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1789\"\u003e\u003cp data-start=\"1712\" data-end=\"1789\"\u003e\u003cspan data-start=\"1712\" data-end=\"1733\" style=\"font-weight: 600;\"\u003eOutput contact:\u003c\/span\u003e\u003cbr data-start=\"1733\" data-end=\"1736\"\u003e- \u003cspan data-start=\"1740\" data-end=\"1751\" style=\"font-weight: 600;\"\u003eNO + NC\u003c\/span\u003e, dry contact\u003cbr data-start=\"1766\" data-end=\"1769\"\u003e- \u003cspan data-start=\"1782\" data-end=\"1789\" style=\"font-weight: 600;\"\u003e5 A\u003c\/span\u003e load\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1796\" data-end=\"1810\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1799\" data-end=\"1810\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplication\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"1812\" data-end=\"1859\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe relay is designed to protect devices such as:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1861\" data-end=\"1973\"\u003e\n\u003cli data-start=\"1861\" data-end=\"1881\"\u003e\u003cp data-start=\"1863\" data-end=\"1881\"\u003ethree-phase motors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1882\" data-end=\"1896\"\u003e\u003cp data-start=\"1884\" data-end=\"1896\"\u003ecompressors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1909\"\u003e\u003cp data-start=\"1899\" data-end=\"1909\"\u003epumps\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1935\"\u003e\u003cp data-start=\"1912\" data-end=\"1935\"\u003eair conditioning units\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1936\" data-end=\"1973\"\u003e\u003cp data-start=\"1938\" data-end=\"1973\"\u003egeneral industrial and domestic loads\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1975\" data-end=\"1987\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtects against:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1989\" data-end=\"2087\"\u003e\n\u003cli data-start=\"1989\" data-end=\"2001\"\u003e\u003cp data-start=\"1991\" data-end=\"2001\"\u003eovervoltage\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2014\"\u003e\u003cp data-start=\"2004\" data-end=\"2014\"\u003eundervoltage\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2032\"\u003e\u003cp data-start=\"2017\" data-end=\"2032\"\u003ephase failure\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2033\" data-end=\"2059\"\u003e\u003cp data-start=\"2035\" data-end=\"2059\"\u003eincorrect phase sequence\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2087\"\u003e\u003cp data-start=\"2062\" data-end=\"2087\"\u003eloss of neutral conductor\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2094\" data-end=\"2120\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"2097\" data-end=\"2120\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIMPORTANT NOTICE\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"2122\" data-end=\"2267\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cspan data-start=\"2125\" data-end=\"2152\" style=\"font-weight: 600;\"\u003eThe relay does NOT regulate voltage!\u003c\/span\u003e\u003cbr data-start=\"2152\" data-end=\"2155\"\u003eIt is only used to \u003cem data-start=\"2170\" data-end=\"2187\"\u003edisconnect the load\u003c\/em\u003e during dangerous conditions in the network, not to stabilize or compensate the voltage.\u003c\/font\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Yes","offer_id":56749118259581,"sku":"GKM-02F","price":47.76,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":56749118292349,"sku":"GKM-02","price":49.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_3845dd88-ec26-47ef-b588-f03e0aa46317.webp?v=1755800085"},{"product_id":"rgt-mt18-reactive-power-controller-18-level-tcr-with-rs485-modbus","title":"RGT-MT18 - Reactive power controller 18 level +TCR with RS485 ModBus","description":"\u003cp\u003e\u003cstrong\u003e18 steps + TCR Power factor controller for symmetrical\/asymmetrical networks with 5 inch touch screen and RS-485 (TENSE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eReactive power control relays are designed to reduce reactive power (inductive and capacitive) that is not used by the load and is drawn from the grid. When inductive power is drawn from the grid, it intervenes by removing a capacitor at an appropriate value. If the capacitive power is drawn from the mains, it intervenes by taking a shunt inductor at the appropriate value. In this way, it attempts to reduce the inductive\/active and capacitive\/active speeds of the system. It is designed to provide more reasonable compensation in unbalanced inductive and capacitive systems with the RGT-MT18 TCR step \u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eGenerator input and generator compensation\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eVoltage, harmonic current\/voltage, inductive and capacitive alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHit, discharge and settling times can be adjusted\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRemote communication with RS485 (RS485 ModBus RTU)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSingle-phase, two-phase and three-phase capacitor and shunt reactor can be connected\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eHarmonic voltage and current can be observed up to 61st harmonics\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTotal energy (import\/export) can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTHD-V and THD-I values of each phase can be observed\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eCreate power analysis (20 samples 9999 min.) - for capacitor selection\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eTemperature alarm output\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDemand registration (active and reactive and apparent power and current demand)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMinimum, maximum and average current and voltage values of each phase can be monitored\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eActual date and time\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":56749123010941,"sku":"RGT-MT18","price":334.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/29021cc84c53911daf6559abe27a8950_f1fe03ca-01bd-403b-b5a7-b93dd5d5367b.png?v=1755800184"},{"product_id":"metal-mounting-base-for-signal-posts-o70","title":"Metal mounting base for signal posts ø70","description":"\u003cp\u003e\u003cstrong\u003eMetal mounting base for signal posts ø70, manufacturer MUCCO (Turkey)\u003c\/strong\u003e\u003c\/p\u003e","brand":"MUCCO","offers":[{"title":"Default Title","offer_id":56749206045053,"sku":"SNT-70TB","price":15.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/f9cf9749b405f057b00329530a697f4a_e668e6dc-56dd-4301-8e4c-9c40466460c3.jpg?v=1755802861"},{"product_id":"mounting-base-for-signal-posts-folding-base-o70","title":"Mounting Base for Signal Posts \/ Folding Base ø70","description":"\u003cp\u003e\u003cstrong\u003eMounting base for signal posts\/ Folding base for ø70, manufacturer MUCCO (Turkey) \u003c\/strong\u003e\u003c\/p\u003e","brand":"MUCCO","offers":[{"title":"Default Title","offer_id":56749206077821,"sku":"SNT-70D","price":15.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/4ef428bb09a9a0044661505fa6cda7aa_9c09a64a-8243-4324-bfc6-87f50fbd22fc.jpg?v=1755802889"},{"product_id":"instrumental-measurement-of-transformer-current","title":"Instrumental measurement of transformer current","description":"\u003cp\u003e\u003cstrong\u003eSlide-on measuring transformer for primary rated currents from 600 to 1200 A, secondary current 5 A, rated outputs 3.75 to 20 VA, available in 0.5S accuracy class.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSlip-on current transformer for indirect measurement of sinusoidal AC currents.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eMounting of the transformer is either by means of mounting feet, which are included.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"600\/5","offer_id":56749260407165,"sku":"TK606005304","price":27.2,"currency_code":"EUR","in_stock":false},{"title":"800\/5","offer_id":56749260439933,"sku":"TK608005307","price":26.0,"currency_code":"EUR","in_stock":true},{"title":"1000\/5","offer_id":56749260472701,"sku":"TK6010005310","price":34.4,"currency_code":"EUR","in_stock":false},{"title":"1200\/5","offer_id":56749260505469,"sku":"TK6012005310","price":38.64,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_01cff222-72c7-49ac-8f9a-a82d92fe09f8.png?v=1755805678"},{"product_id":"dc-ac-electronic-single-phase-solid-state-relay-ssr-switching-contact-25a-40a","title":"DC-AC electronic single phase solid state relay SSR switching contact 25A, 40A","description":"\u003cp\u003e\u003cstrong\u003eDC-AC single phase electronic solid state relay SSR switching contact 25A, 40A, for mounting on 35mm DIN rail. \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eDC input 3-32 VDC, AC output circuit 24-380 VAC (thyristors), high number of switching cycles (no contact material burn), noiseless switching and low excitation power.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"25A","offer_id":56749260734845,"sku":"IG3PA-4825D","price":28.96,"currency_code":"EUR","in_stock":true},{"title":"40A","offer_id":56749260767613,"sku":"IG3PA-4840D","price":30.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_42c8342b-ce7a-4c67-9144-cfdfb8b8f46f.jpg?v=1755805709"},{"product_id":"tk40-current-measuring-transformer-300-5-400-5-500-5-600-5-800-5","title":"TK40 - Current measuring transformer 300\/5 400\/5 500\/5 600\/5 800\/5","description":"\u003ch1 data-start=\"137\" data-end=\"185\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"139\" data-end=\"185\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eMeasuring current transformer TK40 - TENSE\u003c\/font\u003e\u003c\/span\u003e\u003c\/h1\u003e\u003cp data-start=\"187\" data-end=\"483\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"187\" data-end=\"206\" style=\"font-weight: 600;\"\u003eProduct description:\u003c\/span\u003e\u003cbr data-start=\"206\" data-end=\"209\"\u003eThe measuring window of the TK40 current transformer is designed for indirect AC current measurement in low voltage installations and industrial applications. The transformer converts high primary current to standard secondary current suitable for measuring, controlling or protecting equipment.\u003c\/p\u003e\u003cp data-start=\"485\" data-end=\"500\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"485\" data-end=\"500\" style=\"font-weight: 600;\"\u003eFeatures:\u003c\/span\u003e\u003c\/p\u003e\u003cul data-start=\"501\" data-end=\"942\"\u003e\n\u003cli data-start=\"501\" data-end=\"553\"\u003e\u003cp data-start=\"503\" data-end=\"553\"\u003ePrecision current conversion with \u003cspan data-start=\"543\" data-end=\"551\" style=\"font-weight: 600;\"\u003e0.5S\u003c\/span\u003e accuracy class\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"554\" data-end=\"617\"\u003e\u003cp data-start=\"556\" data-end=\"617\"\u003eCompact and durable housing made of non-flammable, flame retardant ABS\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"618\" data-end=\"695\"\u003e\u003cp data-start=\"620\" data-end=\"695\"\u003eTerminal block with non-removable cover, suitable for high gauge conductors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"696\" data-end=\"746\"\u003e\u003cp data-start=\"698\" data-end=\"746\"\u003eResistance to short-circuit current: Ith = 60 × In\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"747\" data-end=\"797\"\u003e\u003cp data-start=\"749\" data-end=\"797\"\u003eResistance to constant current: Id = 1 × In\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"798\" data-end=\"835\"\u003e\u003cp data-start=\"800\" data-end=\"835\"\u003eOperating temperature: -25 °C ... +85 °C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"836\" data-end=\"866\"\u003e\u003cp data-start=\"838\" data-end=\"866\"\u003eMounting: KK0001 or KK0002\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"867\" data-end=\"909\"\u003e\u003cp data-start=\"869\" data-end=\"909\"\u003eTest voltage: 3 kV for 1 minute\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"910\" data-end=\"942\"\u003e\u003cp data-start=\"912\" data-end=\"942\"\u003eMax. system voltage: 0.72 kV\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"949\" data-end=\"975\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"952\" data-end=\"975\"\u003eTechnical parameters\u003c\/span\u003e\u003c\/h2\u003e\u003cdiv\u003e\u003cspan data-start=\"952\" data-end=\"975\" style=\"font-weight: 600;\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan lang=\"PL\" style=\"line-height: 16.1px; font-family: Aptos, sans-serif;\"\u003eVariants available\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"PL\"\u003e300\/5A, 400\/5A, 500\/5A, 600\/5A, 800\/5A\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad capacity\u003c\/td\u003e\n\u003ctd\u003e3.75 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy class\u003c\/td\u003e\n\u003ctd\u003e0,5S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary winding\u003c\/td\u003e\n\u003ctd\u003e40 × 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner hole (conductor diameter)\u003c\/td\u003e\n\u003ctd\u003eØ 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact current limitation\u003c\/td\u003e\n\u003ctd\u003eFS 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eKK0001 \/ KK0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eNon-flammable, flame retardant ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/span\u003e\u003c\/div\u003e\u003cp data-start=\"1332\" data-end=\"1422\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"1332\" data-end=\"1342\" style=\"font-weight: 600;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp data-start=\"1332\" data-end=\"1422\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"1332\" data-end=\"1342\" style=\"font-weight: 600;\"\u003eStandards:\u003c\/span\u003e\u003cbr data-start=\"1342\" data-end=\"1345\"\u003eIEC 60044-1, IEC 61869-2, VDE 0414-1, DIN 57414, BS3938, BS7626, EN 61869-2\u003c\/p\u003e\u003cp data-start=\"1424\" data-end=\"1599\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"1424\" data-end=\"1445\" style=\"font-weight: 600;\"\u003eQuality control:\u003c\/span\u003e\u003cbr data-start=\"1445\" data-end=\"1448\"\u003eEach transformer is individually tested at the factory, the results are recorded in a test report and attached to the transformer.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"300\/5","offer_id":56749260865917,"sku":"TK403005302","price":19.48,"currency_code":"EUR","in_stock":true},{"title":"400\/5","offer_id":56749260898685,"sku":"TK404005303","price":19.48,"currency_code":"EUR","in_stock":true},{"title":"500\/5","offer_id":56749260931453,"sku":"TK405005306","price":20.68,"currency_code":"EUR","in_stock":false},{"title":"600\/5","offer_id":56749260964221,"sku":"TK406005306","price":22.8,"currency_code":"EUR","in_stock":true},{"title":"800\/5","offer_id":56749260996989,"sku":"TK408005307","price":24.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_6b0e5e8c-4cae-4eb4-882e-e04cf5927812.png?v=1755805724"},{"product_id":"tk30-current-measuring-transformer-150-5-200-5-250-5-300-5-400-5-500-5-600-5","title":"TK30 - Current measuring transformer 150\/5 200\/5 250\/5 300\/5 400\/5 500\/5 600\/5","description":"\u003ch2 data-start=\"155\" data-end=\"228\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"158\" data-end=\"228\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eWindow type measuring current transformer TK30 series made by Turkish company TENSE\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003ch3 data-start=\"230\" data-end=\"252\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"234\" data-end=\"252\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct Description\u003c\/font\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cp data-start=\"253\" data-end=\"569\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWindow type current measuring transformer is designed for indirect measurement of sinusoidal alternating currents in electrical systems.\u003cbr data-start=\"372\" data-end=\"375\"\u003eSuitable for professional use in industry, meter cabinets, measurement and control systems.\u003cbr data-start=\"479\" data-end=\"482\"\u003eMounting is possible with mounting feet \u003cspan data-start=\"524\" data-end=\"534\" style=\"font-weight: 600;\"\u003eKK0001\u003c\/span\u003e or \u003cspan data-start=\"540\" data-end=\"550\" style=\"font-weight: 600;\"\u003eKK0002\u003c\/span\u003e (included).\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"576\" data-end=\"604\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"579\" data-end=\"604\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical specifications\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003ch3 data-start=\"606\" data-end=\"634\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"610\" data-end=\"634\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eElectrical parameters\u003c\/font\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003ch3 data-start=\"606\" data-end=\"634\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan dm=\"\" sans sans-serif font-size:=\"\" font-weight:=\"\" normal style=\"color: rgb(51, 51, 51);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSlide-on measuring transformer for primary rated currents from 150 to 600 A, secondary current 5 A, rated outputs 1 to 10 VA, available in 0.5S accuracy class.\u003c\/font\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003ch3 data-start=\"846\" data-end=\"874\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"850\" data-end=\"874\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMechanical parameters\u003c\/font\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cul data-start=\"875\" data-end=\"1129\"\u003e\n\u003cli data-start=\"875\" data-end=\"926\"\u003e\u003cp data-start=\"877\" data-end=\"926\"\u003e\u003cspan data-start=\"877\" data-end=\"913\" style=\"font-weight: 600;\"\u003ePrimary winding (bore section):\u003c\/span\u003e 30 × 10 mm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"927\" data-end=\"956\"\u003e\u003cp data-start=\"929\" data-end=\"956\"\u003e\u003cspan data-start=\"929\" data-end=\"946\" style=\"font-weight: 600;\"\u003eRound wire:\u003c\/span\u003e Ø 26 mm\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"999\"\u003e\u003cp data-start=\"959\" data-end=\"999\"\u003e\u003cspan data-start=\"959\" data-end=\"971\" style=\"font-weight: 600;\"\u003eHousing:\u003c\/span\u003e non-flammable flame retardant ABS\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1000\" data-end=\"1129\"\u003e\n\u003cp data-start=\"1002\" data-end=\"1020\"\u003e\u003cspan data-start=\"1002\" data-end=\"1018\" style=\"font-weight: 600;\"\u003eTerminal block:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-start=\"1023\" data-end=\"1129\"\u003e\n\u003cli data-start=\"1023\" data-end=\"1045\"\u003e\u003cp data-start=\"1025\" data-end=\"1045\"\u003eNon-removable cover\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1048\" data-end=\"1088\"\u003e\u003cp data-start=\"1050\" data-end=\"1088\"\u003eSuitable for high cross-section conductors\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1091\" data-end=\"1129\"\u003e\u003cp data-start=\"1093\" data-end=\"1129\"\u003eBrass clamps for higher safety\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1131\" data-end=\"1145\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1135\" data-end=\"1145\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eInstallation\u003c\/font\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cul data-start=\"1146\" data-end=\"1221\"\u003e\n\u003cli data-start=\"1146\" data-end=\"1190\"\u003e\u003cp data-start=\"1148\" data-end=\"1190\"\u003eMounting type: \u003cspan data-start=\"1162\" data-end=\"1172\" style=\"font-weight: 600;\"\u003eKK0001\u003c\/span\u003e or \u003cspan data-start=\"1178\" data-end=\"1188\" style=\"font-weight: 600;\"\u003eKK0002\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1191\" data-end=\"1221\"\u003e\u003cp data-start=\"1193\" data-end=\"1221\"\u003eEasy to slide onto the conductor\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1223\" data-end=\"1260\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1227\" data-end=\"1260\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThermal and operational properties\u003c\/font\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cul data-start=\"1261\" data-end=\"1424\"\u003e\n\u003cli data-start=\"1261\" data-end=\"1303\"\u003e\u003cp data-start=\"1263\" data-end=\"1303\"\u003e\u003cspan data-start=\"1263\" data-end=\"1284\" style=\"font-weight: 600;\"\u003eOperating temperature:\u003c\/span\u003e -25 °C to +85 °C\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1304\" data-end=\"1370\"\u003e\u003cp data-start=\"1306\" data-end=\"1370\"\u003e\u003cspan data-start=\"1306\" data-end=\"1360\" style=\"font-weight: 600;\"\u003eShort-term short-circuit current immunity (Ith):\u003c\/span\u003e 60 × In\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1371\" data-end=\"1424\"\u003e\u003cp data-start=\"1373\" data-end=\"1424\"\u003e\u003cspan data-start=\"1373\" data-end=\"1413\" style=\"font-weight: 600;\"\u003eResistance to continuous current (Id):\u003c\/span\u003e 1.2 × In\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 data-start=\"1426\" data-end=\"1439\" style=\"font-family: \" open=\"\" sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1430\" data-end=\"1439\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStandards\u003c\/font\u003e\u003c\/span\u003e\u003c\/h3\u003e\u003cp data-start=\"1440\" data-end=\"1541\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eManufactured in accordance with:\u003cbr data-start=\"1461\" data-end=\"1464\"\u003eIEC 60044-1, IEC 61869-2, VDE 0414-1, DIN 57414, BS 3938, BS 7626, EN 61869-2\u003c\/font\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"150\/5","offer_id":57071490597245,"sku":"TK301505301","price":16.8,"currency_code":"EUR","in_stock":true},{"title":"200\/5","offer_id":57071490630013,"sku":"TK302005302","price":16.8,"currency_code":"EUR","in_stock":true},{"title":"250\/5","offer_id":57071490662781,"sku":"TK302505303","price":16.8,"currency_code":"EUR","in_stock":true},{"title":"300\/5","offer_id":57071490695549,"sku":"TK303005303","price":16.8,"currency_code":"EUR","in_stock":true},{"title":"400\/5","offer_id":57071490728317,"sku":"TK304005305","price":16.8,"currency_code":"EUR","in_stock":true},{"title":"500\/5","offer_id":57071490761085,"sku":"TK305005306","price":16.8,"currency_code":"EUR","in_stock":false},{"title":"600\/5","offer_id":57071490793853,"sku":"TK306005307","price":16.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_56fb6dae-f099-40f7-a66b-df1aee949060.png?v=1755805768"},{"product_id":"tk30s-current-measuring-transformer-100-5-150-5-200-5-250-5-300-5-400-5-500-5","title":"TK30S - Current measuring transformer 100\/5 150\/5 200\/5 250\/5 300\/5 400\/5 500\/5","description":"\u003cp\u003e\u003cstrong\u003eSlide-on measuring transformer for primary rated currents from 100 to 500 A, secondary current 5 A, rated outputs 2.5 VA, available in accuracy class 0.5.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSlip-on current transformer for indirect measurement of sinusoidal alternating currents\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe mounting of the transformer is either by means of the mounting feet included in the delivery.\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"100\/5","offer_id":56749264765309,"sku":"TK30S1005102","price":13.24,"currency_code":"EUR","in_stock":false},{"title":"150\/5","offer_id":56749264798077,"sku":"TK30S1505203","price":10.0,"currency_code":"EUR","in_stock":true},{"title":"200\/5","offer_id":56749264830845,"sku":"TK30S2005203","price":13.24,"currency_code":"EUR","in_stock":true},{"title":"250\/5","offer_id":56749264863613,"sku":"TK30S2505203","price":13.24,"currency_code":"EUR","in_stock":true},{"title":"300\/5","offer_id":56749264896381,"sku":"TK30S3005203","price":13.24,"currency_code":"EUR","in_stock":false},{"title":"400\/5","offer_id":56749264929149,"sku":"TK30S4005203","price":13.24,"currency_code":"EUR","in_stock":false},{"title":"500\/5","offer_id":56749264961917,"sku":"TK30S5005203","price":13.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_2ebd99a9-80e6-43e3-b7f3-9a232d38abd5.png?v=1755805891"},{"product_id":"liquid-level-relay-for-steam-boilers-well-or-tank","title":"Liquid level relay for steam boilers (well or tank)","description":"\u003ch1 data-start=\"123\" data-end=\"184\"\u003e\u003cstrong data-start=\"125\" data-end=\"184\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eRelay for water level control in boiler and steam generator\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"186\" data-end=\"207\"\u003e\u003cstrong data-start=\"189\" data-end=\"207\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"208\" data-end=\"485\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe water level control relay is designed for use in \u003cstrong data-start=\"263\" data-end=\"316\"\u003eboilers, steam generators and water heating systems\u003c\/strong\u003e where it provides automatic shutdown of the electric heating system when there is insufficient water in the tank.\u003cbr data-start=\"401\" data-end=\"404\"\u003eIt prevents the heater from running \"dry\", protecting the equipment and extending its life.\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"487\" data-end=\"600\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe device works with two independent capacity systems - \u003cstrong data-start=\"547\" data-end=\"570\"\u003eTANK (well\/tank)\u003c\/strong\u003e and \u003cstrong data-start=\"573\" data-end=\"599\"\u003eBOILER (boiler\/heater)\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"607\" data-end=\"628\"\u003e\u003cstrong data-start=\"609\" data-end=\"628\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eEquipment functions\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch3 data-start=\"629\" data-end=\"667\"\u003e\u003cstrong data-start=\"633\" data-end=\"667\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTank level control (TANK)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"668\" data-end=\"833\"\u003e\n\u003cli data-start=\"668\" data-end=\"767\"\u003e\n\u003cp data-start=\"670\" data-end=\"767\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAs long as the water level is \u003cstrong data-start=\"692\" data-end=\"715\"\u003eabove the TANK electrode\u003c\/strong\u003e, the pump runs (the \"motor operation\" indicator is lit).\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"768\" data-end=\"833\"\u003e\n\u003cp data-start=\"770\" data-end=\"833\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the water level falls \u003cstrong data-start=\"791\" data-end=\"813\"\u003ebelow the TANK electrode\u003c\/strong\u003e, the pump switches off.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"835\" data-end=\"883\"\u003e\u003cstrong data-start=\"839\" data-end=\"883\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eBoiler\/heater level control (BOILER)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"884\" data-end=\"1106\"\u003e\n\u003cli data-start=\"884\" data-end=\"962\"\u003e\n\u003cp data-start=\"886\" data-end=\"962\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the \u003cstrong data-start=\"915\" data-end=\"925\"\u003eBOILER\u003c\/strong\u003e sensor level is reached, the pump switches off - the tank is full.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"963\" data-end=\"1106\"\u003e\n\u003cp data-start=\"965\" data-end=\"1106\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the level in the boiler drops \u003cstrong data-start=\"994\" data-end=\"1018\"\u003ebelow the BOILER electrode\u003c\/strong\u003e, a 10-second delay is triggered, after which the pump automatically switches on and refills the water.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1108\" data-end=\"1159\"\u003e\u003cstrong data-start=\"1112\" data-end=\"1159\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eElectric water heating control (RES Elect)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1160\" data-end=\"1343\"\u003e\n\u003cli data-start=\"1160\" data-end=\"1249\"\u003e\n\u003cp data-start=\"1162\" data-end=\"1249\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the water in the boiler reaches the \u003cstrong data-start=\"1196\" data-end=\"1209\"\u003eRES Elect\u003c\/strong\u003e level, the heater will switch on (indicator light off).\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1250\" data-end=\"1343\"\u003e\n\u003cp data-start=\"1252\" data-end=\"1343\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the level falls below the \u003cstrong data-start=\"1287\" data-end=\"1300\"\u003eRES\u003c\/strong\u003e Elect, the heater will switch off and the indicator light will come on.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1345\" data-end=\"1420\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThis feature protects the heater from overheating or destruction when the tank is empty.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"1427\" data-end=\"1451\"\u003e\u003cstrong data-start=\"1429\" data-end=\"1451\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWiring (overview)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul data-start=\"1452\" data-end=\"1858\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1588\"\u003e\n\u003cp data-start=\"1454\" data-end=\"1588\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1454\" data-end=\"1467\"\u003eCom Elect\u003c\/strong\u003e - common electrode (must be connected to the metal body of the tank\/boiler; if not conductive, use a separate electrode)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1589\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1591\" data-end=\"1644\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1591\" data-end=\"1605\"\u003eTank Elect\u003c\/strong\u003e - well\/tank level electrode\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1645\" data-end=\"1693\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1693\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1663\"\u003eBoiler Elect\u003c\/strong\u003e - boiler level electrode\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1694\" data-end=\"1743\"\u003e\n\u003cp data-start=\"1696\" data-end=\"1743\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1696\" data-end=\"1709\"\u003eRes Elect\u003c\/strong\u003e - electrode for heater control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1744\" data-end=\"1791\"\u003e\n\u003cp data-start=\"1746\" data-end=\"1791\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1746\" data-end=\"1757\"\u003eRes Out\u003c\/strong\u003e - output for heater connection\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1792\" data-end=\"1858\"\u003e\n\u003cp data-start=\"1794\" data-end=\"1858\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1794\" data-end=\"1807\"\u003eWater Not\u003c\/strong\u003e - output for the signal light (no water)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-start=\"1865\" data-end=\"1890\"\u003e\u003cstrong data-start=\"1867\" data-end=\"1890\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eImportant notice\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul data-start=\"1891\" data-end=\"2184\"\u003e\n\u003cli data-start=\"1891\" data-end=\"1962\"\u003e\n\u003cp data-start=\"1893\" data-end=\"1962\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1893\" data-end=\"1929\"\u003eThe electrodes are not included\u003c\/strong\u003e - they must be ordered separately.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1963\" data-end=\"2059\"\u003e\n\u003cp data-start=\"1965\" data-end=\"2059\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWe also recommend purchasing \u003cstrong data-start=\"1992\" data-end=\"2014\"\u003e3 pieces of 2 A circuit breakers\u003c\/strong\u003e to protect the input and output circuits.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2109\"\u003e\n\u003cp data-start=\"2062\" data-end=\"2109\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWire the relay \u003cstrong data-start=\"2075\" data-end=\"2106\"\u003eexactly according to the manufacturer's diagram\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2110\" data-end=\"2184\"\u003e\n\u003cp data-start=\"2112\" data-end=\"2184\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the receptacle is not conductive, a special common electrode must be used.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1 data-start=\"2191\" data-end=\"2216\"\u003e\u003cstrong data-start=\"2193\" data-end=\"2216\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTechnical parameters\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul data-start=\"2217\" data-end=\"2461\"\u003e\n\u003cli data-start=\"2217\" data-end=\"2251\"\u003e\n\u003cp data-start=\"2219\" data-end=\"2251\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2219\" data-end=\"2240\"\u003eRated voltage:\u003c\/strong\u003e 220 V AC\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2252\" data-end=\"2292\"\u003e\n\u003cp data-start=\"2254\" data-end=\"2292\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2254\" data-end=\"2281\"\u003eOperating voltage range:\u003c\/strong\u003e 90-110%\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2320\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2320\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2295\" data-end=\"2309\"\u003eFrequency:\u003c\/strong\u003e 50\/60 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2321\" data-end=\"2343\"\u003e\n\u003cp data-start=\"2323\" data-end=\"2343\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2323\" data-end=\"2334\"\u003ePower consumption:\u003c\/strong\u003e \u0026lt; 3 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2344\" data-end=\"2380\"\u003e\n\u003cp data-start=\"2346\" data-end=\"2380\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2346\" data-end=\"2367\"\u003eOperating temperature:\u003c\/strong\u003e -40...+50 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2381\" data-end=\"2415\"\u003e\n\u003cp data-start=\"2383\" data-end=\"2415\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2383\" data-end=\"2397\"\u003eConnection:\u003c\/strong\u003e screw terminals\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2416\" data-end=\"2461\"\u003e\n\u003cp data-start=\"2418\" data-end=\"2461\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2418\" data-end=\"2429\"\u003eMounting:\u003c\/strong\u003e DIN rail or mounting panel\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong data-start=\"2470\" data-end=\"2486\" style=\"font-family: inherit; color: rgb(25, 32, 39); font-size: 28px;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePackage contents\u003c\/font\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cul data-start=\"2487\" data-end=\"2593\"\u003e\n\u003cli data-start=\"2487\" data-end=\"2521\"\u003e\n\u003cp data-start=\"2489\" data-end=\"2521\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eRelay for water level control\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2522\" data-end=\"2593\"\u003e\n\u003cp data-start=\"2524\" data-end=\"2593\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDocumentation \/ wiring diagram\u003cbr data-start=\"2553\" data-end=\"2556\"\u003e\u003cem data-start=\"2556\" data-end=\"2593\" style=\"\"\u003e(Electrodes not included)\u003c\/em\u003e\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":56749281575293,"sku":"SSR-19","price":33.44,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/1f260439db01cbf624587c651e27f3cf_1ace0ba7-777e-4820-a81f-1bc583231527.png?v=1755807341"},{"product_id":"liquid-level-relay-for-steam-boilers","title":"Liquid level relay for steam boilers","description":"\u003ch1 data-start=\"172\" data-end=\"268\"\u003e\u003cstrong data-start=\"174\" data-end=\"268\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eWater level control relay for one tank with heater protection - Tense SSR-09\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-start=\"270\" data-end=\"291\"\u003e\u003cstrong data-start=\"273\" data-end=\"291\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProduct description\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"292\" data-end=\"593\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe SSR-09 relay from \u003cstrong data-start=\"319\" data-end=\"328\"\u003eTense\u003c\/strong\u003e is a modern unit designed for \u003cstrong data-start=\"360\" data-end=\"398\"\u003eautomatic water level control\u003c\/strong\u003e in boilers, storage tanks and water heaters.\u003cbr data-start=\"440\" data-end=\"443\"\u003eIt ensures \u003cstrong data-start=\"453\" data-end=\"483\"\u003ereliable water supply\u003c\/strong\u003e, \u003cstrong data-start=\"485\" data-end=\"512\"\u003etimely pump shutdown\u003c\/strong\u003e and, above all, effective \u003cstrong data-start=\"533\" data-end=\"592\"\u003eprotection of the electric heating element against dry running\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"595\" data-end=\"730\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe device uses capacitive electrodes to monitor the water level and automatically controls the pump and heater according to the current situation in the tank.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"737\" data-end=\"758\"\u003e\u003cstrong data-start=\"740\" data-end=\"758\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eKey advantages\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"759\" data-end=\"1363\"\u003e\n\u003cli data-start=\"759\" data-end=\"852\"\u003e\n\u003cp data-start=\"761\" data-end=\"852\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"761\" data-end=\"792\"\u003eDry-running protection\u003c\/strong\u003e for both the boiler and the heater - extends the life of the equipment.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"966\"\u003e\n\u003cp data-start=\"855\" data-end=\"966\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"855\" data-end=\"892\"\u003eAutomatic water level control\u003c\/strong\u003e: the pump switches on when the water level is low and switches off when it reaches the upper level.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"967\" data-end=\"1077\"\u003e\n\u003cp data-start=\"969\" data-end=\"1077\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"969\" data-end=\"989\"\u003eHeater protection\u003c\/strong\u003e - if no water is present at the heater, the device immediately blocks its power supply.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1078\" data-end=\"1152\"\u003e\n\u003cp data-start=\"1080\" data-end=\"1152\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1080\" data-end=\"1104\"\u003eLED indication of\u003c\/strong\u003e pump and heater\u003cstrong data-start=\"1080\" data-end=\"1104\"\u003eoperation\u003c\/strong\u003e for easy status checking.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1153\" data-end=\"1231\"\u003e\n\u003cp data-start=\"1155\" data-end=\"1231\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1155\" data-end=\"1179\"\u003eEasy installation\u003c\/strong\u003e - DIN rail mounting, clear screw terminals.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1232\" data-end=\"1274\"\u003e\n\u003cp data-start=\"1234\" data-end=\"1274\"\u003e\u003cstrong data-start=\"1234\" data-end=\"1272\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCompact dimensions, low consumption.\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1275\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1277\" data-end=\"1363\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1277\" data-end=\"1322\"\u003eWide operating voltage range of 170-260 VAC\u003c\/strong\u003e - stable operation even during power fluctuations.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1370\" data-end=\"1393\"\u003e\u003cstrong data-start=\"1373\" data-end=\"1393\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eOperating principle\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1394\" data-end=\"1450\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe SSR-09 works with two electrodes located in the tank:\u003c\/font\u003e\u003c\/p\u003e\n\u003col data-start=\"1452\" data-end=\"1837\"\u003e\n\u003cli data-start=\"1452\" data-end=\"1589\"\u003e\n\u003cp data-start=\"1455\" data-end=\"1491\"\u003e\u003cstrong data-start=\"1455\" data-end=\"1489\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eLower electrode (min. level)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1495\" data-end=\"1589\"\u003e\n\u003cli data-start=\"1495\" data-end=\"1589\"\u003e\n\u003cp data-start=\"1497\" data-end=\"1589\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf the water level drops below this electrode, the relay activates the pump and starts pumping water.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1591\" data-end=\"1694\"\u003e\n\u003cp data-start=\"1594\" data-end=\"1630\"\u003e\u003cstrong data-start=\"1594\" data-end=\"1628\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThe upper electrode (max. level)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1634\" data-end=\"1694\"\u003e\n\u003cli data-start=\"1634\" data-end=\"1694\"\u003e\n\u003cp data-start=\"1636\" data-end=\"1694\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWhen the upper level is reached, the relay automatically switches off the pump.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1696\" data-end=\"1837\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1740\"\u003e\u003cstrong data-start=\"1699\" data-end=\"1738\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtective electrode at the heating element\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1744\" data-end=\"1837\"\u003e\n\u003cli data-start=\"1744\" data-end=\"1837\"\u003e\n\u003cp data-start=\"1746\" data-end=\"1837\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIf there is no water at the heater, the relay will cut off power to the heater and prevent overheating.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"1839\" data-end=\"1915\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eThis intelligent logic ensures safe and economical operation of the entire system.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"1922\" data-end=\"1936\"\u003e\u003cstrong data-start=\"1925\" data-end=\"1936\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eUsing\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1937\" data-end=\"2133\"\u003e\n\u003cli data-start=\"1937\" data-end=\"1985\"\u003e\n\u003cp data-start=\"1939\" data-end=\"1985\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eElectric boilers and storage water heaters\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1986\" data-end=\"2023\"\u003e\n\u003cp data-start=\"1988\" data-end=\"2023\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eHeating systems with storage tank\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2024\" data-end=\"2062\"\u003e\n\u003cp data-start=\"2026\" data-end=\"2062\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDomestic and industrial water storage tanks\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2063\" data-end=\"2092\"\u003e\n\u003cp data-start=\"2065\" data-end=\"2092\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eWaterworks and pumping systems\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2093\" data-end=\"2133\"\u003e\n\u003cp data-start=\"2095\" data-end=\"2133\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDrinking or domestic water tanks\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"2140\" data-end=\"2168\"\u003e\u003cstrong data-start=\"2143\" data-end=\"2168\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eInstallation and connection\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2169\" data-end=\"2404\"\u003e\n\u003cli data-start=\"2169\" data-end=\"2220\"\u003e\n\u003cp data-start=\"2171\" data-end=\"2220\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMounting on standard \u003cstrong data-start=\"2192\" data-end=\"2205\"\u003eDIN rail\u003c\/strong\u003e in the cabinet.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2221\" data-end=\"2264\"\u003e\n\u003cp data-start=\"2223\" data-end=\"2264\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConnection via \u003cstrong data-start=\"2240\" data-end=\"2261\"\u003escrew terminals\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2265\" data-end=\"2331\"\u003e\n\u003cp data-start=\"2267\" data-end=\"2331\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eElectrodes must be installed in the tank at the required levels.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2332\" data-end=\"2404\"\u003e\n\u003cp data-start=\"2334\" data-end=\"2404\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFor stable operation, the manufacturer recommends the use of \u003cstrong data-start=\"2387\" data-end=\"2403\"\u003eminimum 2.5 mm²\u003c\/strong\u003e conductors.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2406\" data-end=\"2499\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"2406\" data-end=\"2419\" style=\"\"\u003eNote:\u003c\/strong\u003e The electrodes (level probes) are not included and must be ordered separately.\u003c\/font\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":56749281608061,"sku":"SSR-09","price":31.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/331942fa669f949c300016097ee9dafe_9d390c56-794f-4a59-ba29-e1a8676c493c.png?v=1755807349"},{"product_id":"garden-outdoor-wall-lamp-e27-25cm-black-plastic","title":"Garden outdoor wall lamp, E27 25cm black plastic","description":"\u003cp\u003e\u003cstrong\u003eGarden lamp, plastic, E27, 25 cm, max 26W, BAFRA, made in Turkey\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eMain use is for garden lighting, parking lot. The high degree of protection IP54 allows the installation of lamps in places directly exposed to the weather.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe luminaire housing and lens is made of plastic .\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe luminaire subtly and atmospherically illuminates any type of building and garden and gives it a unique decorative effect.\u003c\/p\u003e\u003cp\u003eSuitable for all types of bulbs with E27 base maximum output 26W\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput voltage : 220-240V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eInterchangeable light source: Yes\u003c\/li\u003e\n\u003cli\u003eSocket : E27, max 26W\u003c\/li\u003e\n\u003cli\u003eColor: Black\u003c\/li\u003e\n\u003cli\u003eProtection : IP54\u003c\/li\u003e\n\u003cli\u003eHeight : 250mm\u003c\/li\u003e\n\u003cli\u003eTop diameter: 90 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bafra","offers":[{"title":"Default Title","offer_id":56749290783101,"sku":"BFR840","price":13.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/954238fb653187f3662cfe42d9fd6514_8602b656-dcde-4a0b-a472-30a038d96021.jpg?v=1755808492"},{"product_id":"garden-outdoor-wall-mounted-mushroom-light-e27-25cm-black-plastic","title":"Garden outdoor wall mounted mushroom light, E27 25cm black plastic","description":"\u003ch2\u003eGarden lamp, plastic, E27, 25 cm, max 26W, BAFRA, made in Turkey\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain use is for garden lighting, parking lot. The high degree of protection IP54 allows the installation of lamps in places directly exposed to the weather.\u003c\/p\u003e\n\u003cp\u003eThe luminaire housing and lens is made of plastic .\u003c\/p\u003e\n\u003cp\u003eThe luminaire subtly and atmospherically illuminates any type of building and garden and gives it a unique decorative effect.\u003c\/p\u003e\n\u003cp\u003eSuitable for all types of bulbs with E27 base maximum output 26W\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage : 220-240V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eInterchangeable light source: Yes\u003c\/li\u003e\n\u003cli\u003eSocket : E27, max 26W\u003c\/li\u003e\n\u003cli\u003eColor: Black\u003c\/li\u003e\n\u003cli\u003eProtection : IP54\u003c\/li\u003e\n\u003cli\u003eHeight : 250mm\u003c\/li\u003e\n\u003cli\u003eTop diameter : 190 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bafra","offers":[{"title":"Default Title","offer_id":56749290914173,"sku":"BFR880","price":13.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/706b9fad8328d79c2caf6299facba336_5dfb39f5-7159-4792-9175-80d8a9627627.jpg?v=1755808499"},{"product_id":"led-bulb-candle-e14-7w-610lm-50w-equivalent","title":"LED bulb candle e14 7w 610lm, 50w equivalent","description":"\u003cp\u003e\u003cstrong\u003eLED bulb candle E14 7w 610lm, 50w equivalent, BAFRA, made in Turkey\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eHighly efficient LED candle bulb at a great price. This is a 220-230V., 50-60Hz type LED bulb. These E14 SMD LED bulbs with a wattage of only 7W shine about the same as a regular 50W bulb - the luminous flux is 630 lumens.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLED bulb specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLuminous flux: 630 Lm\u003c\/li\u003e\n\u003cli\u003eWattage: 7W\u003c\/li\u003e\n\u003cli\u003eDimmability: No\u003c\/li\u003e\n\u003cli\u003eEquivalent to a conventional bulb: 50W\u003c\/li\u003e\n\u003cli\u003eInput Voltage : 220-240V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eE14\u003c\/li\u003e\n\u003cli\u003eColour variant: Warm white \/3200K Cold white \/6500K\u003c\/li\u003e\n\u003cli\u003eCRI: \u0026gt;80\u003c\/li\u003e\n\u003cli\u003eAngle of light: 210°\u003c\/li\u003e\n\u003cli\u003eLED chip: SMD\u003c\/li\u003e\n\u003cli\u003eLifetime: 20 000h\u003c\/li\u003e\n\u003cli\u003eProtection: IP20\u003c\/li\u003e\n\u003cli\u003eDimensions : 110x37mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Bafra","offers":[{"title":"Cold white - 6500K","offer_id":56749294453117,"sku":"BFR217-B","price":1.24,"currency_code":"EUR","in_stock":true},{"title":"Warm white - 3200K","offer_id":56749294485885,"sku":"BFR217-G","price":1.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_438c2542-5ac4-4621-95e9-15ebaacaf19e.jpg?v=1755808663"},{"product_id":"20w-led-bulb-e27-150w","title":"20W LED bulb, E27, (150W)","description":"\u003cp\u003e\u003cstrong\u003e20W LED bulb, E27, (150W), BAFRA, made in Turkey\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe BFR2ХХ series is a range of powerful E27 base LED lamps designed for use in domestic and industrial environments where there is a need to provide high lumen output and not break the bank on electricity bills.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eThe standard socket also allows conventional incandescent bulbs to be replaced in luminaires with limited heat output.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eYou can choose between cool white light and warm white light by selecting the appropriate product code using \"-B\" or \"-G\"\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLED bulb specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLuminous flux\u003ci\u003e:\u003c\/i\u003e 1800 Lm\u003c\/li\u003e\n\u003cli\u003eWattage: 20W\u003c\/li\u003e\n\u003cli\u003eDimmability: No\u003c\/li\u003e\n\u003cli\u003eConventional bulb equivalent: 150W\u003c\/li\u003e\n\u003cli\u003eInput Voltage : 220-240V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eE27\u003c\/li\u003e\n\u003cli\u003eColour variant: Warm white \/3200K Cold white \/6500K\u003c\/li\u003e\n\u003cli\u003eCRI: \u0026gt;80\u003c\/li\u003e\n\u003cli\u003eAngle of illumination: 210°\u003c\/li\u003e\n\u003cli\u003eLED chip: SMD\u003c\/li\u003e\n\u003cli\u003eLifetime: 20 000h\u003c\/li\u003e\n\u003cli\u003eProtection: IP20\u003c\/li\u003e\n\u003cli\u003eDimensions : 145x85mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bafra","offers":[{"title":"Cold white - 6500K","offer_id":56749299106173,"sku":"BFR260-B","price":5.75,"currency_code":"EUR","in_stock":true},{"title":"Warm white - 3200K","offer_id":56749299138941,"sku":"BFR260-G","price":10.84,"currency_code":"EUR","in_stock":false},{"title":"Studena bílá - 6500K","offer_id":56749299171709,"sku":"BFR220-B","price":4.2,"currency_code":"EUR","in_stock":false},{"title":"Teplá bílá - 3200K","offer_id":56749299204477,"sku":"BFR220-G","price":4.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_50aec440-982a-49b3-8f47-0d64c2c4ebb2.jpg?v=1755808838"},{"product_id":"led-panel-square-54w-4320lm-600x600mm-ip40-white","title":"LED panel square 54W 4320Lm, 600x600mm, IP40, white","description":"\u003cp\u003e\u003cstrong\u003eLED luminaire square panel 54W 4320Lm, 600x600mm, IP40, white , BAFRA, made in Turkey\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eLED panel has replaced traditional fluorescent lamps, which are widely used in offices, public areas, as well as in shops and shopping malls. One of the most important advantages of LED panels is their very small size and high luminous intensity. This 54W LED panel produces up to 4320 lumens of light. The LED panels can be used in suspended ceilings, plasterboard ceilings - as a recessed\/plug-in luminaire or, if an adapter is used, as a plug-in luminaire.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 220 \/ 240V AC , 50Hz-60Hz(power supply included)\u003c\/li\u003e\n\u003cli\u003eShade colour: white\u003c\/li\u003e\n\u003cli\u003eDimension: 59,5 x 59,5 x 3 cm\u003c\/li\u003e\n\u003cli\u003eWattage: 54W\u003c\/li\u003e\n\u003cli\u003eChromaticity temperature: 3200K\/4500K\/6000K\u003c\/li\u003e\n\u003cli\u003eLuminous flux: 4320Lm\u003c\/li\u003e\n\u003cli\u003eMaterial: aluminium housing, PVC shade\u003c\/li\u003e\n\u003cli\u003eLifetime: ~25,000 hours\u003c\/li\u003e\n\u003cli\u003eDimmability: NO\u003c\/li\u003e\n\u003cli\u003eBeam angle: 150°\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Bafra","offers":[{"title":"Cold white - 6500K","offer_id":56749299597693,"sku":"BFR615-B","price":21.84,"currency_code":"EUR","in_stock":false},{"title":"Warm white - 3200K","offer_id":56749299663229,"sku":"BFR615-G","price":21.84,"currency_code":"EUR","in_stock":false},{"title":"Neutral white - 4000K","offer_id":56749299695997,"sku":"BFR615-N","price":21.84,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/file_a1197b52-1717-443a-8e33-10937f86f1c0.jpg?v=1755808919"},{"product_id":"garden-outdoor-wall-lamp-e27-25cm-black-plastic-1","title":"Garden outdoor wall lamp, E27 25cm black plastic","description":"\u003ch2\u003eGarden lamp, plastic, E27, 25 cm, max 26W, BAFRA, made in Turkey\u003c\/h2\u003e\n\u003cp\u003eMain use is for garden lighting, parking lot. The high degree of protection IP54 allows the installation of lamps in places directly exposed to the weather.\u003c\/p\u003e\n\u003cp\u003eThe luminaire housing and lens is made of plastic .\u003c\/p\u003e\n\u003cp\u003eThe luminaire subtly and atmospherically illuminates any type of building and garden and gives it a unique decorative effect.\u003c\/p\u003e\n\u003cp\u003eSuitable for all types of bulbs with E27 base maximum output 26W\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage : 220-240V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eInterchangeable light source: Yes\u003c\/li\u003e\n\u003cli\u003eSocket : E27, max 26W\u003c\/li\u003e\n\u003cli\u003eColor: Black\u003c\/li\u003e\n\u003cli\u003eProtection : IP54\u003c\/li\u003e\n\u003cli\u003eHeight : 250mm\u003c\/li\u003e\n\u003cli\u003eTop diameter : 100 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bafra","offers":[{"title":"Default Title","offer_id":56749299958141,"sku":"BFR860-1","price":13.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/5af1bf2c2ed0ea2c25cd7e221792e8c7_dbe4f852-5661-4b7f-bb54-9ec9a8786621.jpg?v=1755808961"},{"product_id":"outdoor-garden-column-column-lamp-e27-40cm-plastic-1","title":"Outdoor garden column \/ column lamp E27 40cm plastic","description":"\u003ch2\u003e\u003cstrong\u003eOutdoor garden post\/column lamp E27 40cm plastic, max 26W, BAFRA, made in Turkey\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMain use is for garden lighting, parking lot lighting. The high degree of protection IP54 allows the installation of lamps in places directly exposed to the weather.\u003c\/p\u003e\n\u003cp\u003eThe luminaire housing and lens is made of plastic .\u003c\/p\u003e\n\u003cp\u003eThe luminaire subtly and atmospherically illuminates any type of building and garden and gives it a unique decorative effect.\u003c\/p\u003e\n\u003cp\u003eSuitable for all types of bulbs with E27 base maximum output 26W\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage : 220-240V AC, 50-60Hz\u003c\/li\u003e\n\u003cli\u003eInterchangeable light source: Yes\u003c\/li\u003e\n\u003cli\u003eSocket : E27, max 26W\u003c\/li\u003e\n\u003cli\u003eColor: Black\u003c\/li\u003e\n\u003cli\u003eProtection : IP54\u003c\/li\u003e\n\u003cli\u003eDimensions : 120x120x400mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bafra","offers":[{"title":"Default Title","offer_id":56749299990909,"sku":"BFR850-1","price":13.24,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/1791\/3469\/files\/e84a3d5aa82b405a58e809de2f88edfd_2ced50d5-2cdf-488b-8175-1f83bfbe1469.jpg?v=1755808965"}],"url":"https:\/\/pelek-ie.com\/collections\/special-offers.oembed","provider":"PELEK_IE","version":"1.0","type":"link"}